小型制药冷冻干燥机日常维护和保养!
check beforerunning:每次开机前要例行检查
üthe state of variousvalves (absorbing, exhausting valves for compressors, service valves, capped valves and etc.)
所有截止阀(压缩机吸、排气阀、供液阀、手阀等)处于开启状态;
üpressure meter: 0.6~0.7mpa
压力表正常读数:0.6~0.7mpa
ülevel of compressor oil: 1/4~3/4
压缩机正常油位:1/4~3/4;
after power supply, please notice:送电后应注意
üwhether compressor collects the refrigerant
压缩机是否自动收液;
üwhether difference-oil pressure resets
油压差是否复位等;
after running, please notice:开机后注意
üwhether the sound of compressor is normal, if not, please check power supply
压缩机运行声音是否正常,如果异常请先检查供电的三相电是否平衡;
üwhether the refrigerating piping vibrates normally, if yes, please fix the loosen parts
制冷管路是否有异常振动,如果有则采用相应的固定措施;
üwhether the flux of refrigerant is normal by observing the sight glass, if having bubble in sight glass, please check the content of refrigerant and thermostatic valves
视液镜流量是否正常,若有气泡,则说明制冷剂缺少或膨胀阀流量太大;
üthe state of frosting on the thermostatic valves
膨胀阀结霜情况;
üthe state of frosting on the compressor
压缩机回霜情况;
ücompressor oil return, generally, 1/3~3/4
冷冻油的回油情况;(一般保持在油视镜的1/3~3/4)
compressor start-up:压缩机启动
üstart frequentlyas little as possible, internal more than 3min
不能频繁启动,间隔的时间应大于3min;