bqg-2118industrialonlinezirconiaoxygenanalyzer
technicalindexes
1.measuringrange:0~20.6%02
2.accuracy:≤±2%fs
3.temperatureoffluegasmeasured:≤600℃(lowtemperaturetype);600~800℃(hightemperaturetype)
4.excessaircoefficientoffluegasmeasured:0.1-99
5.responsetime:≤3seconds(90%response)
6.currentoutput:0~10madcor4-20madc
7.powersupply:220v±10%50hz±5%
8.workingconditions:ambienttemperature:0~50℃relativehumidity:<85%
9.heating-uptimeoftheheaterofzirconiadetector:approx20minutes
10.overalldimensionanddimensionofthehole
type
overalldimensionmm
dimensionoftheholemm(height*width)
horizontal(h)
160x80x120
152+1×76+1
vertical(z)
80x160x120
76+1×152+1
square(q)
160x160x200
152+1×152+1
wallmounting(g)
220x170x75(heightxwidthxthickness)
bqg-2118zirconiaoxygenanalyzerispracticalandreliableon-lineautomaticoxygenanalyzer.itsmeasurementanddisplaysystemconsistsofanoxygendetector(sensor)andadisplayinstrument(transmitter).thedetectorismadeofheat-resistingandanti-corrosionmaterialsandcanbedirectlyinsertedintofluesformeasurementofoxygen.thedisplayinstrumentadoptssingle-chipcontrolandcanbeusedincombinationwithvariouselectricunitcombinationinstrument,maindisplayrecorderinstrumentsanddistributedcontrolsystems(dcs).
zirconiaoxygenanalyzerisusedforrapidandaccurateon-linemeasurementandanalysisoftheoxygencontentsinthefluegasproducedbycombustionequipment,suchasboilers,furnacesandheaters,soastorealizecontroloflow-oxygencombustion,energysavingandpollutiontreatment.
features
thesensorismadeofheat-resistingandanti-corrosionmaterialswithhighreliability.
withaspecialstructuraldesign,thisanalyzerdoesn’tneedexternalairpump,andthereferenceaircanrealize
convectionbyitself.
thesensorhasastandardairinterface,whichenablescalibrationcheckonthesiteandprovidesconvenient
maintenance.
itadoptssingle-chipcontrolanddataprocessingwithquickresponse,accuratemeasurementandstable
performance.